Skip to main content
kurtyna powietrzna EliS G

Air curtain ELiS G

ELiS G air curtain is a high-performance unit for use in the doorways of large industrial facilities. The purpose of the curtain is to protect the door opening against heat loss, especially in areas subject to prolonged abrasion, such as warehouse doors. The curtains can be combined into larger units and installed horizontally or vertically.

Product description

The housing is made of galvanised steel and plastic elements. Adjustable outlet grille allows the user to set the correct angle of the supply air stream. The long reach of the unit, together with appropriate mounting on both sides of the door opening, can provide a barrier as wide as 14m. They are available in three sizes 1.5, 2 and 2.5m and in three versions with water exchanger, with electric heaters and without heating. 

ELiS G can be equipped with a control unit, which makes it possible to switch the air curtain on and off, connect a door sensor and thermostat, as well as protect and safeguard the fan against overload. The air curtain also fully cooperates with other devices within the FLOWAIR SYSTEM, thus creating intelligent solutions that bring comfort and savings.

ELiS G baner

Basic parameters

Basic parameters
Max. range 8 m
Air flow 2400 -12800 m3/h
Mass 35,6 – 68,1 kg
Casing Galvanized steel

The housing made of galvanised steel and plastic elements is perfect for warehouse conditions.

 ELiS G units are equipped with high-performance 3-speed fans.

As standard, the air curtain is equipped with universal brackets that allow vertical and horizontal mounting to partitions.

The use of an indoor air curtain reduces energy losses due to air mixing. It prevents the influx of cold air into the heated space in winter and the influx of warm air into the air-conditioned space in summer, thus keeping the temperature at the optimum level.

SYSTEM FLOWAIR

SYSTEM FLOWAIR, the intelligent control

The ELiS G air curtain is suitable for integration within a BMS system and for SYSTEM FLOWAIR, i.e. intelligent control for responsible energy management in the facility. Centrally controlled systems result in real savings and ensure comfortable temperature all year round. The devices can also be controlled by basic TS automation.

ELiS G technical data

G-E-150 G-N-150 G-W-150 G-W-150 2R G-E-200 G-N-200 G-W-200 G-W-200 2R G-E-250 G-N-250 G-W-250
Power supply [V/Hz] 3x400 / 50 230 / 50 230 / 50 230 / 50 3x400 / 50 230 / 50 230 / 50 230 / 50 3x400 / 50 230 / 50 230 / 50
Max. power consumption [kW](1) 13,5 + 0,68 0,67 0,67 0,67 20,5 + 1,05 1,05 1,05 1,05 24,5 + 1,4 1,4 1,4
Max. current concumption [A](1) 19,5 + 3,0 3 3 3 29,5 + 4,5 4,5 4,5 4,5 36,0 +  6,0 6 6
Fan IP 20 54 54 54 20 54 54 54 20 54 54
Connection - - 3/4 3/4 - - 3/4 3/4 - - 3/4
Airflow [m3/h](2) 2600-6300 2800-6550 2500-6200 2400-6100 3400-9400 3900-9700 3300-9100 3100-8800 4900 - 12400 4900 -12800 4300-12000
Acoustic pressure level [dB(A)] - 5 m(3) 44-65 44-65 45-66 46-67 45-66 45-66 46-68 47-69 46-68 46-68 47-69
Acoustic pressure level [dB(A)] - 3 m(3) 45-66 45-66 46-67 47-68 46-67 46-67 47-69 48-70 47-69 47-69 48-70
Sound power level [dB(A)](4) 60-81 60-81 61-82 62-83 61-82 61-82 62-84 63-85 62-84 62-84 63-85
Heating power [kW](5) 13,5 - 7,8-27 18,7-62,9 20,5 - 8,7-30,0 9-30 24,5 - 15,0-49,6
Max. water temperature [oC] - - 120 120 - - 120 120 - - 120
Max. operating pressure [MPa] - - 1,6 1,6 - - 1,6 1,6 - - 1,6
Temperature increase (△T) [oC](5) 7,0-16,0 - 4,0-13,0 8,0-29,0 7,0-18,0 - 3,0-11,0 8-27 7,5-16,5 - 4,0-12,0
Mass [kg] 39,1 35,6 40,7 44,3 53,1 48,4 53,5 57,1 64,8 61,1 68,1
Range [m](2) 7,5 8 7,5 7,5 7,5 8 7,5 7,5 7,5 8 7,5
(1) for G-E, the parameters of heating elements powered by 3N 400V and fans powered by 1N 230V
(2) according to ISO 27327-1
(3) acoustic pressure level has been measured in a 1500m3 space with a medium sound absorption coefficient, directional factor: Q=2
(4) acoustic power level according to ISO 27327-2
(5) G-W power and temperature range specified for the parameters: fan speed III, heating medium temperature 50/40oC device inlet temperature 20OC - fan speed III, heating medium temperature 90/70oC device inlet temperature 0oC; G E temperature range specified for the parameters: 3rd power step, fan speed III – 3rd power step, fan speed I

Do you need to check the heating power of the device or select it for the facility?

ELiS G Intallation

Installation options

The ELiS G air curtain comes standard with a set of brackets for horizontal and vertical mounting. In both cases, the unit is mounted to load-bearing structures using pins or additional brackets.

The overall dimensions of the door must not exceed:
- for vertical single-sided installation up to 8.0 m,
- for vertical double-sided assembly 14 m,
- for horizontal installation up to 8.0 m.

montaż elisg

ELiS G dimensions

wymiary ELiS G 150
wymiary ELiS G 200
wymiary ELiS G 250

Download files

Want to learn more about the product? Check the technical documentation, design files or marketing materials prepared for you.

Catalog card pdf pobierz
Certificates pdf pobierz
Technical Documentation pdf pobierz
Revit files zip pobierz
CAD files dwg pobierz
T-box

Want to know more?

Remember that we are here to help you at every stage of implementation. Do you need help selecting devices or design, or maybe you have some questions about the product? Contact us, we will help.